C Series ADC
Virtual appliance support (up to 40Gbps Layer 7 throughput) runs on all major virtualization platforms to provide full-featured load balancing and application delivery. All virtual appliances have flexible payment options: perpetual license, annual or monthly subscription. Ideal for small and medium businesses, this virtual appliance delivers 100 percent uptime for mission-critical applications while staying with
LuccitechProducts/Platform
Luccitech offers hardware and virtual appliance options to meet your requirements.
virtualDevice Support(up40Gbps of Layer 7 throughput) in allmainstreamvirtualization platform to provide a fully functionalLoad Balancingand application delivery. all virtual appliances have flexible payment options: perpetual license, annual or monthly subscription. This virtual appliance is ideal for small and medium businesses and can provide mission-critical applications100 percent uptime while staying within your budget.
AllLuccitech ADC hardware platform (up to 320Gbps Layer 4 throughput) is designed with high performance in mind. In a Luccitech ADC hardware model with a dedicated ASIC chip SSL accelerator, it can easily achieve 190,000 SSL TPS at a better speed than a back-end server with a general-purpose CPU.
powerful load balancing
from Layer 4 TCP/UDP to Layer 7 applications, Luccitech client requests can be distributed through a comprehensive load balancing methodloadto back-end servers, including polling, weight polling, least connections, least connections by weight, prediction, response speed by weight, and source IP hash.
Luccitech support persistence using cookies or source IP or HTTP headers to reliably direct client requests to the same back-end application server during a session.
Contentstrategy
Contentstrategybased on 7 layers effectiveloaddistributes client requests to servers, including URL, URL token, HTTP method, HTTP request, HTTP content, and source IP.
Health Check
Luccitech collects backend server metrics through ICMP, TCP echo, Telnet, RDP, LDAP, HTTP(S), FTP, MAIL, DNS, NNTP, and other probes.
High Availability/Active-Active Cluster
Critical Applications100 percent of the time is a requirement. Luccitech product line has a high availability design, whenapplication fails or is overloaded, the client request will beschedulingto an available server. ByHA deployment, when the master Luccitech unit goes down, the slave Luccitech unit becomes the master node to eliminate a single point of failure. The Luccitech also supports cluster deployment, where client requests are distributed across all cluster nodes to provide high throughput and scalability. In addition, GSLB can provide multi-site failover: when the primary data center is shut down, traffic will beschedulingto the alternate data center.
offers professional products from 3G-320G performance
Basic Edition (vs F5 LTM) (Basic load functions include local load, service acceleration, device management, HA and cluster support, etc.)
Advanced Edition (Super Application Gateway) includes multi-cloud zero trust, cloud native hardening, protocol optimization, application security, business quality assurance module and
multi-cloud protocol optimization module (GSLB Vs F5 GTm) : global load, application and API flow control, protocol conversion and optimization including protocol conversion and adaptive support for IPv6, HTTP2.0, UDP, S3, SDN and other related industrial internet of things and storage
Multi-cloud Zero Trust Module (AAA VS F5 APM): Supports distributed heterogeneous data centers such as central, edge federated authentication, pre-authentication, single sign-on, and encrypted connection.
Cloud Native Reinforcement Module: K8s Container Adaptation (VS F5 k8s solution)
application protection module:( WAF VS F5 ASM) application and API security include WAF, vRlues programmable security, IPS engine and other high-quality security modules for anti-blackmail insurance business: including Netflow module: in-depth health check of business, abnormal alarm and audit related to uninterrupted business security.
Advanced Networking
Luccitechsupports single arm, multi arm and serverdirect connectionReturnmultiple waysdeployment and support NAT,SNATand transparency route frames between the client and the real server.
Luccitechfully supportedIPv6,VLAN/VXLAN, port binding and backup give you the flexibility you need.
Luccitechfully supportedIPv6,VLAN/VXLAN, port binding and backup give you the flexibility you need.
Virtual Platform Support (Cloud Advantage)
Luccitechvirtual appliances are designed to run on all leading virtualization platforms and bring application control features such as load balancing, enhanced security, optimized application delivery and failover support-all without the need for proprietary hardware. All our virtual products are available for free trial14days.
Luccitechvirtual devices are available inVMware,Microsoft Hyper-V,Oracle VirtualBoxandKVM. It can be extended10Gbps's No.7layer throughput.
Powerful hardware platform
Luccitechhardware platform provides the scalability, performance, and security needed to meet the growing functional demands of large data centers.
a proprietary operating system installed on the hardware platform (Luccitech Cloud OS) for many with linear scalability.CPUhas been tuned to provide high-performance packet processing to support large-scale deployments.
ownership
Luccitechincludes all feature sets, including server load balancing, global server load balancing, single sign-on,Weban application firewall. All functions are available at no additional cost.
Luccitechoffers features and performance at an attractive price to help reduce business application delivery solutions.TCO.
easy to manage
Luccitechprovides an intuitive graphical user interface to manage the various functions of the system.
Network
Integration 4/Layer 7
supportsingle arm, multi arm
support direct server return
based onnat
VLAN Trunk (802.1Q)
Link Aggregation(802.3ad)
supportVXLAN
supports full localIPv6 management and features
SLB-PT (protocol translation),
SLB-64 (IPv4<->IPv6,IPv6<->IPv4)
SNAT
state failover
Virtualization
supportVMwareESXi, Microsoft Hyper-V,Oracle VirtualBoxandKVM and other types of private public cloud
hypervisor acceleration and management integration
Management
dedicated management interface (GUI, CLI, SSH)
Web User Interface
real-time packet capture for analysis and debugging
Comprehensive Reports and Logs
Role-Based Administration
LuccitechADC-LCAHardwareversion
LCA 3023GM |
LCA 323 |
LCA 1023 |
|
performance |
|||
throughput (L4/L7) |
32Gbps/30Gbps(Hardware)+ 32Gbps/30Gbps (soft load) |
3.5Gbps/3Gbps |
10.8Gbps/10Gbps |
SSL TPS(2k key) |
35,000 |
5,000 |
10,000 |
Concurrent Connections |
80,000,000 |
8,500,000 |
35,000,000 |
maximum number of concurrency in seven layers |
525,000 |
125,000 |
262,500 |
Layer -4 Links per Second |
850,000 |
75,000 |
450,000 |
Layer -4 requests per second |
2,600,000 |
260,000 |
800,000 |
seven layersHTTPrequest processing per second |
1,400,000 |
170,000 |
175,000 |
Network Interface |
|||
Giga Copper |
8 |
6 |
6 |
Gigabit Fiber |
4 |
4 |
4 |
10GE fiber optic |
8 |
0 |
2 |
Hardware Specifications |
|||
Processor |
8 nuclear |
2 nuclear |
4nuclear |
Memory(ECCRAM) |
64GB |
8GB |
32GB |
Storage |
1TB SSD |
120GB SSD |
120GB SSD |
ASIC EncryptionHardware |
is |
is |
is |
Dimensions(WxDxH) |
430mm (W) x 350mm (D) x 44mm (H) |
430mm (W) x 350mm (D) x 44mm (H) |
430mm (W) x 350mm (D) x 44mm (H) |
Rack Unit (mountable) |
1U |
1U |
1U |
Unit Weight |
9 kgs |
9 kgs |
9kgs |
power supply |
Redundancy300WATX |
ATX Single Power Supply |
1U Redundant 300WATX |
form |
1U hardware + soft load authorization + unified management platform |
1U Hardware |
1U Hardware |
Operating Range |
temperature0 °-40°C | Humidity 10%-85% |
Next Generation Load Balancing and Super Application Gateway (Intelligent Multi-Cloud Application Deliverer) and Delivery Platform
LuccitechADC-LCAHardwareversion
LCA 1523 |
LCA 2023 |
LCA 2523 |
LCA 4023 |
|
performance |
||||
17Gbps/15Gbps |
20Gbps/20Gbps |
27Gbps/25Gbps |
42Gbps/40Gbps |
|
SSL TPS(2k key) |
14,000 |
14,000 |
35,000 |
35,000 |
Concurrent Connections |
40, 000,000,000 |
75,800,000 |
80,000,000 |
80,000,000 |
maximum number of concurrency in seven layers |
262,500 |
525,000 |
525,000 |
525,000 |
Layer -4 Links per Second |
450,000 |
725,000 |
725,000 |
850,000 |
Layer -4 requests per second |
1,600,000 |
2,000,000 |
2,000,000 |
2,600,000 |
seven layersHTTPrequest processing per second |
800,000 |
1,100,000 |
1,100,000 |
1,400,000 |
Network Interface |
||||
16 |
4 |
4 |
0 |
|
Gigabit Fiber |
optional |
optional |
optional |
optional |
10GE fiber optic |
2 |
4 |
4 |
8 |
Hardware Specifications |
||||
Processor |
4nuclear |
8 nuclear |
8 nuclear |
16 nuclear |
Memory(ECCRAM) |
32GB |
64GB |
64GB |
64GB |
Storage |
120GB SSD |
480GB SSD |
256GB SSD |
512GB SSD |
ASIC EncryptionHardware |
is |
is |
is |
is |
Dimensions (inches) |
430mm (W) x 350mm (D) x 44mm (H) |
430mm (W) x 509mm (D) x 44mm (H) |
430mm (W) x 509mm (D) x 44mm (H) |
430mm (W) x 509mm (D) x 88mm (H) |
Rack Unit (mountable) |
1U |
1U |
1U |
2U |
Unit Weight |
10 kgs |
10 kgs |
10 kgs |
20 kgs |
Redundant power supply |
Redundancy300W ATX |
Redundancy300W ATX |
Redundancy300W ATX |
500W ATXAC power |
form |
1U Hardware |
1U Hardware |
1U Hardware |
2U Hardware |
Operating Range |
temperature0 °-40°C | Humidity 5%-95% |
LuccitechADC-LCAHardwareversion
LCA 6023 |
LCA 8023 |
LCA X023 |
|
performance |
|||
throughput (L4/L7) |
62Gbps/60Gbps |
82Gbps/80Gbps |
102Gbps/100Gbps |
SSL TPS(2k key) |
75,000 |
75,000 |
75,000 |
Concurrent Connections |
100,000,000 |
200,000,000 |
300,000,000 |
maximum number of concurrency in seven layers |
1,050,000 |
1,050,000 |
1,050,000 |
Layer -4 Links per Second |
1,000,000 |
1,000,000 |
1,000,000 |
Layer -4 requests per second |
3,000,000 |
3,000,000 |
3,000,000 |
seven layersHTTPrequest processing per second |
2,000,000 |
2,000,000 |
3,000,000 |
Network Interface |
|||
Giga Copper |
8 |
8 |
8 |
Gigabit Fiber |
optional |
optional |
optional |
10GE fiber optic |
4 |
4 |
4 |
25GE port (SFP28) |
4 |
0 |
0 |
40GE port (QSFP +) |
0 |
4 |
0 |
100GE port (QSFP28) |
0 |
0 |
2 |
Hardware Specifications |
|||
Processor |
24nuclear |
26 nuclear |
26 nuclear |
Memory(ECCRAM) |
128GB |
128GB |
128GB |
Storage |
512GB SSD |
512GB SSD |
512GB SSD |
ASIC EncryptionHardware |
is |
is |
is |
Dimensions (inches) |
430mm (W) x 509mm (D) x 88mm (H) |
430mm (W) x 509mm (D) x 88mm (H) |
430mm (W) x 509mm (D) x 88mm (H) |
Rack Unit (mountable) |
2U |
2U |
2U |
20 kgs |
20 kgs |
20 kgs |
|
Redundant power supply |
500W ATXAC power |
500W ATXAC power |
500WATX AC Power Supply |
form |
2U Hardware |
2U Hardware |
2U Hardware |
Operating Range |
temperature0 °-40°C | Humidity 5%-95% |
Next Generation Load Balancing and Super Application Gateway (Intelligent Multi-Cloud Application Deliverer) and Delivery Platform
LuccitechADC-LCAHardwareversion
LCA-X623 |
LCA-2X23 |
LCA-3X23 |
|
performance |
|||
throughput (L4/L7) |
160bps/160Gbps |
210Gbps/160Gbps |
320Gbps/210Gbps |
SSL TPS(2k key) |
75,000 |
100,000 |
190,000 |
Concurrent Connections |
300,000,000 |
300,000,000 |
400,000,000 |
maximum number of concurrency in seven layers |
3,000,000 |
3,000,000 |
3,000,000 |
Layer -4 Links per Second |
825,000 |
825,000 |
825,000 |
Layer -4 requests per second |
2,600,000 |
2,600,000 |
2,600,000 |
seven layersHTTPrequest processing per second |
3,000,000 |
5,000,000 |
8,000,000 |
Network Interface |
|||
Giga Copper |
2 |
2 |
2 |
Gigabit Fiber |
optional |
optional |
optional |
10GE Fiber Optic |
4 |
4 |
0 |
25GE port (SFP28) |
0 |
0 |
0 |
40GE port (QSFP +) |
0 |
0 |
0 |
100GE port (QSFP28) |
4 |
4 |
8 |
Hardware Specifications |
|||
Processor |
2piece18nuclear |
2piece18 nuclear |
2piece18 nuclear |
Memory(ECCRAM) |
128GB |
128GB |
128GB |
Storage |
1TSSD |
1TSSD |
1TSSD |
ASIC EncryptionHardware |
is |
is |
is |
Dimensions (inches) |
500mm(W) x 600 mm(D) x 88mm(H) |
500mm(W) x 600 mm(D) x 88mm(H) |
500mm(W) x 600 mm(D) x 88mm(H) |
Rack Unit (mountable) |
2U |
2U |
2U |
Unit Weight |
25 kgs |
25 kgs |
25 kgs |
redundant power supply |
500W ATXAC power |
500W ATXAC power |
500WATX AC Power Supply |
form |
2U Hardware |
2U Hardware |
2U Hardware |
Operating Range |
temperature0 °-40°C | Humidity 5%-95% |
AllLuccitech ADC hardware devices supportActive-Activecluster deployment.
specifications, performance figures may change depending on configuration and environmental conditions,Please pay attention to the official website update.